Server failure
This server failed with the error "E171F PCIE Fatal Err B0 D3 F0" during power up. Upon inspection it was found that the 5/I PCIe SAS Controller card model no UCS-51 had a swollen electrolytic capacitor. This was replaced with one from an old PC motherboard, it had the same value (1500uF) and voltage rating (6.3v). After replacement the server booted and completed all it POST and began booting the OS. The server was soak tested and appeared to be operating fine. Hopefully saved an engineer call-out that probably would cost ~£500. By the way the machine was out of warranty. Below are pictures of the board and the repair.

Swollen Capacitor

Capacitor Repair
Supplemental Info A further 5 Dell servers came up with the same error and these were fixed by replacing the capacitors, bad batch of electrolytics.
Read More
Posted in | No comments
Newer Posts Older Posts Home
Subscribe to: Comments (Atom)

Popular Posts

Categories

  • Cluster Login Problem
  • Hadoop Cluster Passwordless SSH login
  • Open-SSH Installation
  • Software Update Command Line

Blog Archive

  • ►  2013 (6)
    • ►  September (3)
    • ►  April (2)
    • ►  March (1)
  • ►  2012 (16)
    • ►  November (1)
    • ►  October (1)
    • ►  July (2)
    • ►  June (3)
    • ►  May (1)
    • ►  April (1)
    • ►  March (3)
    • ►  February (3)
    • ►  January (1)
  • ▼  2011 (17)
    • ►  December (1)
    • ►  November (3)
    • ►  August (4)
    • ►  July (1)
    • ►  June (2)
    • ►  May (2)
    • ►  March (2)
    • ▼  February (1)
      • Dell Poweredge 2950 Failure
    • ►  January (1)
  • ►  2010 (18)
    • ►  December (2)
    • ►  September (2)
    • ►  August (2)
    • ►  July (4)
    • ►  June (7)
    • ►  May (1)
Powered by Blogger.

About Me

Unknown
View my complete profile